Browsing by Author "Nyati, H."
Now showing 1 - 2 of 2
Results Per Page
Sort Options
- ItemEvaluation of test-kits for the detection of Escherichia coli O157 in raw meats and cattle faeces(2012) Nyati, H.; Heuvelink, A.; Van Heerwaarden, C.; Zwartkruis, A.Escherichia coli O157 detection limits in artificially contaminated beef and cattle faeces samples were determined using Dynabeads anti E. coli O157 immunomagnetic beads, VIDAS-UP, VIDAS-ICE, and real-time PCR (GeneDisc and LightCycler) systems. Dynabeads anti-E. coli O157 immunomagnetic separation (IMS) and the GeneDisc cycler were the most sensitive methods, and could detect an initial 1 CFU in 25g beef samples after 6h of incubation in modified tryptone soya broth with novobiocin (mTSB+n) or buffered peptone water (BPW). The VIDAS-UP method could detect an initial 10 CFU, while VIDAS-ICE and the LightCycler methods could only detect an initial 100 CFU. Higher detection rates were achieved with 18 hour incubations, where an initial 1 CFU in a 25g sample could be detected with all five methods. For cattle faeces enrichments, Dynabeads anti-E. coli O157 IMS could detect an initial 1 CFU after a 6 h incubation in mTSB+n, while the VIDAS-UP and VIDAS-ICE methods could detect an initial 10 CFU and both PCR methods could only detect an initial 100 CFU. Detection rates were lower in BPW, compared to mTSB+n, with thresholds of 100 CFU for VIDAS-ICE, VIDAS-UP and GeneDisc methods, and >100 CFU for the LightCycler method.
- ItemInfluence of Organic Material and Biofilms on Disinfectant Efficacy Against Listeria monocytogenes(ISEKI-Food Association (IFA), 2012-04-18) Nyati, H.; Beumer, R.; Van der Veen, S.; Hazeleger, W.; Abee, T.The effects of organic material and biofilm formation on the efficacy of Suma Tab D4 chlorine tablets and Suma Bac D10 quaternary ammonium compound (QAC) against Listeria monocytogenes was determined in suspension and on stainless steel and polystyrene surfaces according to standard disinfectant test methodology. Exposure to 200 and 740 mg L-1 QAC and to 150 mg L-1 active chlorine resulted in a> 5.0 log10 CFU mL-1 and> 5.0 log10 CFU/coupon reduction of six L. monocytogenes strains within one minute, in suspension tests, and on stainless steel surfaces, respectively. Additionally, there was a reduction by as much as 5 log10 CFU/coupon or 5 log10 CFU/well of reference strains EGDe and Scott A biofilms within five minutes on stainless steel and polystyrene surfaces. Organic material, added as bovine serum albumin at 0.3%(w/v) completely prevented the inactivation of L. monocytogenes in 150 mg L-1 chlorine, while reductions of only 0.6+-0.1 log10 CFU mL-1 were recorded in the presence of UHT milk at 3%(v/v). In contrast, reductions of 5 log10 CFU mL-1 were recorded within one minute on exposure to 740 mg L-1 QAC in the presence of 0.3%(w/v) bovine serum albumin and within two minutes in the presence of 20%(v/v) UHT milk. Although Suma D4 chlorine tablets and Suma Bac D10 QAC are effective listericidal agents at recommended concentrations, Suma Tab D4 chlorine efficacy against L. monocytogenes is impaired by the presence of low concentrations of organic material, while Suma Bac D10 QAC maintains its listericidal activity in high organic loads.