In vitro monitoring of rabbit anterior cruciate ligament damage by acoustic emission.

dc.contributor.authorAzangwe, Godfrey
dc.date.accessioned2016-03-24T07:14:07Z
dc.date.accessioned2023-06-26T13:01:48Z
dc.date.available2016-03-24T07:14:07Z
dc.date.available2023-06-26T13:01:48Z
dc.date.issued2000-06
dc.descriptionPublished Journal Articleen_US
dc.description.abstractAnterior cruciate ligament (ACL) rupture is a major clinical problem leading to instability and degeneration of the knee joint. The problem is compounded by the limited ability of the ACL to heal when ruptured. The existing knowledge regarding the way the ACL ruptures is limited, and this investigation is an attempt to understand the nature of the ruptures using the rabbit as a model. A total of 16 rabbit tibia–ACL–femur complexes were stretched in tension to complete rupture. Four specimens were stretched to failure at a displacement rate of 0.5 mm/min and 12 specimens at 10 mm/min. Acoustic emission (AE) transducers were placed on both the tibia and the femur, and stress wave signals generated during the tensile test were recorded. Fibre fractures produced the highest amplitude signals with a relatively longer rise time. Other failure modes such as matrix failure and debonding produced lower amplitude signals with shorter rise times. We also noted that few events were recorded during the initial period of tensile loading (the elastic phase). The activity then increased significantly after maximum load was reached. The location information provided by the acoustic emission system was consistent with the final site of rupture. We have shown that AE can be used to characterise ligament damage, with fibre pull-outs and fibre fracture producing the highest signal amplitudes.en_US
dc.identifier.citationAzangwe, G. 2000. In vitro monitoring of rabbit anterior cruciate ligament damage by acoustic emission. Medical Engineering Physics, 279-283.en_US
dc.identifier.urihttp://196.220.97.103:4000/handle/123456789/653
dc.publisherMedical Engineering Physicsen_US
dc.subjectAcoustic emission monitoringen_US
dc.subjectAnterior cruciate ligament ruptureen_US
dc.subjectTensile testingen_US
dc.subjectLigament failure modesen_US
dc.titleIn vitro monitoring of rabbit anterior cruciate ligament damage by acoustic emission.en_US
dc.typeArticleen_US
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
In vitro monitoring of rabbit anterior cruciate ligament damage by acoustic emission.pdf
Size:
310.45 KB
Format:
Adobe Portable Document Format
Description:
In vitro monitoring of rabbit anterior cruciate ligament damage by acoustic emission
License bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Plain Text
Description: